ULTRASONIC TRANSDUCER FREQUENTLY ASKED QUESTIONS

- Oct 09, 2017-

ULTRASONIC TRANSDUCER FREQUENTLY ASKED QUESTIONS


1. Ultrasonic vibrator damp, you can check the plug with the transducer connected to the plug, check the insulation resistance value can determine the basic situation, the general requirements of insulation resistance greater than 5 megohm, if not reach the insulation resistance, Generally the transducer is damp, you can put the transducer as a whole (not including the spray shell) into the oven set about 100 ℃ drying 3 hours or use the hair dryer to the peak until the normal resistance.

2. Transducer oscillator, ceramic material fragmentation, can be combined with the naked eye and megger combination check, generally as an emergency treatment measures, you can turn off the individual damage to the oscillator, will not affect the normal use of other vibrators.



To find a ULTRASONIC CONVERTER for your reference?