HS520A Ultrasonic Horn Analyzer Frequency Measuring Device High Accuracy
Specification:
| Measure Items | Resonance Frequency: Fs |
| Half Power Frequency: F1 and F2 | |
| Maximum real admittance at Fs: Gmax | |
| Dynamic Resistance: R1 | |
| Anti resonance frequency: Fp | |
| Mechanical quality factor: Qm | |
| Free capacitance: CT | |
| Dynamic inductance: L1 | |
| Dynamic capacitance: C1 | |
| Static capacitance: Co | |
| electromechanical coupling coefficient: Keff and Kp | |
| Maximum real impedance at Fp: Zmax | |
| Measure Diagram | G,B-F |
| G-B (admittance circle coordinate) | |
| R,X-F | |
| R-X (impedance circle coordinate) | |
| Z,phase-F | |
| Y,phase-F | |
| Z(Logarithm),phase-F | |
Size of LCD Screen: 8-inch screen | |
Principle:
An impedance analyzer can measure and evaluate to match the circuit.
For piezoelectric ceramics, you can directly judge the pros and cons of the device from the admittance circle diagram and logarithmic coordinates.If the ceramic wafer is delaminated or cracks appear, the logarithmic curve will appear multimodal, and the admittance circle diagram will appear multiple. Parasitic small circles.
Whether the design, processing and assembly of the horn is reasonable or defective can be clearly seen directly on the guide circle chart.
Applications:
Piezoelectric ceramics, transducers, ultrasonic cleaning machines, ultrasonic plastic welding machine, underwater acoustic, magnetostrictive materials, ultrasonic grinder, ultrasonic atomization , reversing radar, ultrasonic ranging, phacoemulsification , ultrasonic motors, and all other devices used in piezoelectric and ultrasound.
Factory workshop:
Packing :
Shipping and Payment:
Hot Tags: hs520a ultrasonic horn analyzer frequency measuring device high accuracy, China, manufacturers, suppliers, factory