Introduction:
The TRZ Horn Analyzer determines the operation frequency of the item to be tested and its impedance and current with the touch of a button. It’s quick and easy. With this quick and easily retrieved information, the user can perform the quality control of transducers, tuning of sonotrodes and ultrasonic horns, preventive and corrective maintenance of acoustic sets and much more
Specification:
Parameters:
Resonant frequency: Fs,
The maximum conductance :Gmax,
Half power frequency points :F2-F1,
Dynamic resistance :R1,
Parallel or anti resonance frequency :Fp,
Mechanical quality factor :Qm,
Free capacitance :CT,
Dynamic inductance: L1,
Dynamic capacitance :C1,
Static capacitance :CO,
Electromechanical coupling coefficients: Keff.
Planar electromechanical coupling coefficient K:p
Freedom of dielectric constant
Application :
* Operation
* Sonotrode tuning
* Test of transducers
* Test of acoustic sets
* Test of piezo ceramics
* Predictive maintenance
-------------------------
Workshop:
CE Certification:
Packing&Shipping:
Shipping Port:Shanghai
Shipping Term:By express,by air,by ocean and so on.
Leading Time:Quick production leading time and fast delivery.Usually 1-3days if we have in stock.
Payment:
FAQS:
Q:what kinds of graph will display on your impedance analyzer?
A:There are G B-F; LgZ Phi-F; R`X-F; Z Phi-F; Y Phi-F graphs.
Q:What is the PC interface method connect to your analyzer?
A:The interface method is RS232, you can also buy USB-RS232 interface converter.
Q:What is the difference between HS80A/70A and HS520A?
A:We all have update our impedance analyzer from HS80A/70A to HS520A.HS520A is based on the HS70A and HS80A,Portable, more powerful ARM processor.HS520A has large touch screen, you can operate it without PC.