1-1Mhz Impedance Analyzer For Sonotrode

The proper frequency and impedance adjust is indispensable for all ultrasonic devices. The frequency depends mainly on dimensions (e.g.: length of the sonotrode) and the impedance of the quality of material used, assembly, and coupling of the acoustic sets’ parts. Deviations indicate the need for fine tuning, cleaning, re-gripping or re-assembly.


1-1Mhz  Impedance Analyzer for Sonotrode

Ultrasonic Analyzer  (1)analyzer (15)

Ultrasonic Analyzer  (13)

Description :


The impedance analyzer can be measured and rated to match the circuit.

Whether the design, processing and assembly of the horn are reasonable or defective can be seen directly on the circular diagram.


Specification:

Specification.png


Characteristic:



Scope of application: Electrical equipment, electronic components, etc.

Advantage: Easy to use, accurate and inexpensive

Claim: The measured components require five five-center curves

measurement accuracy: Extremely high



Measuring:


(Note: There are differences in the relevant characteristic data of different manufacturers)

Measurement parameters: |Z|, |Y|, θ, R, X, G, B, L, C, D, Q can provide 12 parameter combinations

Test frequency: 100Hz~40MHz (cable length: 0m)

Vibrator level: 10mV~1Vrms (≤10MHz), 10mV~0.5Vrms (>10MHz); (UNKNOWN open), 3-bit resolution

DC offset: 0~±40V, 10mV resolution

Measurement terminal: 4-terminal configuration

Measuring range and highest resolution

Measurement parameter range maximum resolution

Basic measurement accuracy: 0.17 [%]

Level monitoring: 1mV~1 Vrms, 1μA~20mA

Gain-phase measurement

Measurement parameters: Tch/Rch (dB, linear ratio); Tch, Rch (V, dBm, dBv), θ (degrees, radians); Tch = measurement channel: Rch = reference channel, g = group delay

10Hz~100MHz, 1mHz resolution

Aperture frequency range: (group delay measurement) frequency interval 0.5 [%] ~ 100 [%]

Oscillator level: -65dBm~+15dBm, 0.1dB resolution

Measurement range: Tch/Rch: 0~±120dB, 0.001dB resolution; Tch, Rch: -107dBm~-5dBm (0dB attenuator), -87dBm~+15dBm, (20dB attenuator); 0.001dB, resolution: θ: ±180° (using phase scale extension function, continuous display of phase) 0.01° resolution; g: 0.1 ns~1 s, 0.1 ns resolution

Basic measurement accuracy: Tch/Rch: 0.1dB, 0.5°; Tch, Rch: 0.35dBm

Level Monitoring: Monitors the input level of the reference and test channels in dBm, dBV and V.